Chapter 2 wiring – IAI America MSEP User Manual
Page 51
Chapter 2 Wiring
43
Check the previous page for Notes 1 to 6.
EMGINSLOT0
EMGINSLOT1
EMGINSLOT2
EMGINSLOT3
Emergency Stop
Reset Switch
Emergency Stop
Switch
CR1
SIO Connector
CR1
24V
0V
S1
Emergency Stop Control Circuit
Motor Power Supply (Slot 3)
(Axis No.6 and 7)
MPISLOT3
MPOSLOT3
CR2
(Note 2)
MPISLOT2
MPOSLOT2
CR2
(Note 2)
MPOSLOT1
MPISLOT1
CR2
(Note 2)
MPISLOT0
MPOSLOT0
CR2
(Note 2)
Motor Power Supply (Slot 2)
(Axis No.4 and 5)
Motor Power Supply (Slot 1)
(Axis No.2 and 3)
Motor Power Supply (Slot 0)
(Axis No.0 and 1)
MP+24V
0V
CP+24V
0V
Control
Power
External Drive Cutoff •
Emergency Stop Input Connector
Power Line Input Connector
System I/O Connector
MSEP
MPISLOT3
MPOSLOT3
CR2
(Note 2)
MPISLOT2
MPOSLOT2
CR2
(Note 2)
MPOSLOT1
MPISLOT1
CR2
(Note 2)
MPISLOT0
MPOSLOT0
CR2
(Note 2)
MP+24V
0V
CP+24V
0V
EMG+SLOT0
(Note 6)
EMG+SLOT0
EMGINSLOT0
EMG+SLOT1
EMGINSLOT1
EMG+SLOT2
EMGINSLOT2
EMG+SLOT3
EMGINSLOT3
S1
4
3
2
1
12
11
10
9
7
8
5
6
15
16
13
14
1
3
4
2
3
4
3
2
1
12
11
10
9
7
8
5
6
15
16
13
14
1
3
4
2
External Drive Cutoff • Emergency Stop Input Connector
Power Line Input Connector
Emergency Stop Switch on
Teaching Pendant
(Note 6)
S2
(Note1)
EMG A
EMG B
MSEP
8
5
EMG-
EMG+SLOT2
(Note 6)
EMG+SLOT3
(Note 6)
3
2
4
SIO Connector
S2
EMG-
2
4
8
5
(Note1)
(Note 6)
(Note 6)
(Note 6)
CR1
(Note 4)
CR2
(Note 2)
CR1
System I/O Connector
EMG+SLOT1
(Note 6)