Page 130

background image

3.4 Fieldbus

Type

Address Map

122

(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)

Signal Type

Bit

Symbol

Description

Details

Completed

Position No.

(Simple

Alarm Code)

16 bits

PM1 to

PM128

16-bit integer

The positioning complete position number is

output in a binary number once getting into the

positioning width after moving to the target

position.

In the case that the position movement has not

been performed at all, or during the movement,

“0” is output. Read it by turning PEND Signal on

after movement.

The simple alarm code (refer to Chapter 6

Troubleshooting) is output while an alarm is

issued (ALM of Status Signal is ON).

3.8.1 (23)

b15

EMGS

This signal turns ON during an emergency stop

3.8.1 [2]

b14

CRDY

This signal turns ON when the controller is

standing by.

3.8.1 [1]

b13

ZONE2

“ON” for the current position within the zone 2 set

range

The zone range setting is necessary for the

parameter.

b12

ZONE1

“ON” for the current position within the zone 1 set

range

The zone range setting is necessary for the

parameter.

3.8.1 [11]

b11

b10

b9

Cannot be used.

b8

MEND

This signal turns ON at either of positioning

complete, home return complete, pressing

complete or pressing failure, and turns OFF at

movement start.

It is OFF before movement.

3.8.1 [19]

b7

ALML

Light error alarm output

It turns ON when a message level error is issued. 3.8.1 [20]

b6

Cannot be used.

b5

PSFL

This signal turns ON when the actuator missed

the load in push-motion operation.

3.8.1 [18]

b4

SV

This signal turns ON when operation standby is

complete (Servo is ON).

3.8.1 [5]

b3

ALM

This signal is ON while an alarm is generated.

3.8.1 [3]

b2

MOVE

This signal is ON while in movement.

3.8.1 [8]

b1

HEND

This signal turns ON at home return complete and

is kept unless the home position is lost due to a

fact such as an alarm.

3.8.1 [6]

P

LC

O

ut

pu

t

Status

Signal

b0

PEND

This signal turns ON at positioning complete and

is kept ON during a stop with the servo ON, but

does not turn ON when pressing operation is

failed.

3.8.1 [9]