Chapter 5 I/O Parameter

214

[28] Default movement direction for excitation-phase signal detection

(Parameter No.34)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

34 Default movement direction for

excitation-phase signal detection

PHSP

0: Reverse

1: Forward

In accordance

with actuator

Excitation detection

(Note)

starts when the servo is turned ON for the first time after the power is

supplied. Detection direction at this time is determined.

Even though it is generally unnecessary to change this setting, set this to the direction which

the motor is easy to move when the actuator interferes with the mechanical end or peripheral

object at the time the power is supplied.

If the direction not interfering is the same direction as the home return direction, set the same

values as set to Parameter No.17 Home Return Direction. If the direction in opposite, set the

other values from Parameter No.17. (If No.17 is 0, set 1. If No.17 is 1, set 0.)

(Note) In Simple Absolute Type, the excitation phase signal detection is executed at the

home-return operation complete.

[29] Exicitation-phase signal detection time (Parameter No.35)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

35 Exicitation-phase signal detection

time

PHSP

msec

1 to 999

In accordance

with actuator

Excitation detection

(Note)

starts when the servo is turned ON for the first time after the power is

supplied. Detection direction at this time is determined.

Even though it is generally unnecessary to change this setting, changing the setting of this

parameter may be effective when excitation error is generated or abnormal operation is

confirmed.

Please contact us in the case a change is necessary to this parameter.

(Note) In Simple Absolute Type, the excitation phase signal detection is executed at the

home-return operation complete.

[30] Excitation Detection Type (Parameter No.36)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

36 Excitation Detection Type

PHSP

0: Conventional

method

1: New method 1

(For vertical mount

installation)

2: New method 2

(For horizontal

mount in stallation)

0

Excitation detection

(Note)

is executed at the first servo-on after the power is supplied, and in the

new method, we succeeded to make this operation smoother and quieter than ever (if

compared with our existing products).

In the case the new method 2 (horizontal mount installation) is set and the actuator is mounted

vertically, the slider or the rod may drop at the excitation operation. Follow the instructed

orientation to install. If the slide or rod drops with the mentioned way of installation, set with the

current setting.