beautypg.com

IAI America MSEP User Manual

Page 241

background image

Chapter 6

Troubleshooting

233

Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

0E0

Servo

motor

(*)

Only when

connected

Overload

Cause

: 1) The work weight exceeds the rated weight, or an

external force is applied and the load increased.

2) If the actuator is equipped with a brake, the

brake is not released.

3) The slide resistance of the actuator is locally

high.

Treatment : 1) Check the work and its surrounding area to

remove the cause.

2) If an improvement can be confirmed when 24V

DC, 150mA is supplied to BKRLS terminal in the

external brake input connector, a malfunction of

the controller can be considered. Please contact

IAI. If the error cannot be cancelled, malfunction

of brake, cable breakage or controller

malfunction can be considered. Please contact

IAI.

3) In the case that the work can be moved by hand,

move it. Then, check that there is no location

where a sliding resistant is too large. Check if

the installation face is distorted. When the error

occurs in operation of the actuator only, Please

contact IAI.

Caution

Restart the operation after making sure to remove the cause.

If you cannot determine that the cause is removed completely,

wait for at least 30 minutes before turning ON the power to

prevent the motor coil from burning.

0E5

Encoder receipt error

Cause

: This indicates that the data was not received to the

controller in the normal condition from the simple

absolute area.

1) Connector connection error (If the detail code in

the error list of the teaching tool is 0002H.)

2) Effect of noise (If the detail code in the error list

of the teaching tool is 0001H.)

3) Malfunction of component (communication part)

inside the controller.

Treatment : 1) Check if any wire breakage on a connector and

the condition of wire connections.

2) Interrupt the power to the peripheral equipment

and activate only the this actuator and actuator.

If any error does not occur, it might be caused by

noise. Take proper measures against noise.

3) It is necessary to replace the actuator (motor

part) or controller.

If the cause cannot be specified, please contact IAI.

0E7

Servo

motor

(*)

Only when

connected

Cold start

A-, B- and Z-phase wire

breaking

Cause

: Encoder signals cannot be detected correctly.

1) Wire breakage or connector connection error on

an actuator cable or cable enclosed in an

actuator.

2) Malfunction of encoder itself.

Treatment : 1) Check if any wire breakage on a connector and

the condition of wire connections.

If the cables are in the normal condition, the

malfunction of the encoder can be considered.

Please contact IAI.

(*) Servo motor : RCA, RCA2, RCL Series