beautypg.com

6 control of input signal – IAI America MSEP User Manual

Page 154

background image

3.6 Control of Input Signal

146

3.6 Control of Input Signal

3.6.1

PIO Input Signal Process

The input signal of this controller has the input time constant of 7ms considering the prevention

of wrong operation by chattering and noise.

Therefore, input each input signal for 7ms or more

(Note)

continuously. The signal cannot be

identified if it is less than 7ms.

Input Signal

Input Signal

Identify

Not Identify

7ms