3.8 I/O Signal Controls and Function

157

(21) Operation for Positioner 1/Simple Direct Modes

If the position data is written to the target position register (for Simple Direct Mode) or the target

position is set in the position data of MSEP (for Positioner 1 Mode), the operation shall be made

with other information, such as the speed, acceleration/deceleration, pressing width, pressing

force, etc., set to the position data.

Ɣ Example of operation (Normal Positioning Operation with Simple Direct Mode)

(Preparation) Set the axis numbers to be used in Simple Direct Mode with Gateway Parameter

Setting Tool. [Refer to 3.2. Initial Setting.]

Set the position data items (speed, acceleration/deceleration, pressing width,

etc)except for the target position item, in the position table.

1) Set the target position data in the target position register.

2) Set the position No. where the speed and acceleration/deceleration, etc., have been set, in

the setup position No. register.

3) In the condition where the positioning completion (PEND) signal is turned “ON” or under

movement signal (MOVE) is turned “OFF”, turn “ON” the positioning command (CSTR)

signal.

The data items set in Steps 1) and 2) are read in the controller at the startup (ON edge) of

the CSTR signal.

4) After the CSTR signal is turned “ON”, the PEND signal is turned OFF after tpdf.

5) After confirming that the PEND signal is turned “OFF” or MOVE signal is turned “ON”, turn

“OFF” the CSTR signal. Do not change the value in the target position register until the

CSTR signal is turned “OFF”.

6) At the same time when the PEND signal is turned “OFF”, the MOVE signal is turned “ON”.

7) The current position data is continuously updated. When the remaining travel distance

becomes within the range of the positioning width set in the position data, and the CSTR

signal is turned “OFF”, the PEND signal is turned “ON”. Then, the completed position No. is

output to the completed position No. register.

Accordingly, for the read of the completed position No. register when the positioning is

completed, confirm it some time (Remaining Travel Distance Movement Time) after the

PEND signal is turned “ON”.

The current position data might be changed slightly even when the system is stopped.

8) MOVE signal turns OFF at the same time as or within 10ms after PEND signal turns ON.

9) The target position data can be changed during the actuator movement.

In order to change the target position, change the target data and turn ON the CSTR signal

after the time longer than the PLC scanning time has passed.

Ɣ Example of operation (Pressing operation)

For the pressing operation, set the current limit to the pressing force box and pressing width to

the pressing width box in the position data at the stage of (Standard). By conducting a

positioning operation towards the set position number, the actuator performs a pressing

operation.