beautypg.com

IAI America MSEP User Manual

Page 113

background image

3.4 Fieldbus

Type
Address Map

105

(2) List for Input and Output Signal

(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)

Signal Type

Bit

Symbol

Description

Details

b15

MON

Operation control with communication is available

while it is ON

b14

Cannot be used.

b13

RTE

Retained condition of ERR-T or ERR-C during an

operation is cancelled if it is ON

It is the cancel signal when ERR-T or ERR-C

occurrence is set to latch in Gateway Parameter

Setting Tool

b12

b11

b10

b9
b8
b7
b6
b5
b4
b3
b2
b1

Control

signal 0

b0

Cannot be used.

b15
b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4
b3

b2

b1

P

LC

O

ut

pu

t

Control

signal 1

b0

Cannot be used.