4 fieldbus type address map – IAI America MSEP User Manual

Page 148

background image

3.4 Fieldbus

Type

Address Map

140

14) Reading of Alarm-issued Axis Number

PLC Output (Address n is the input and output top address for MSEP.)

(Note) If this command is sent, the response command updates with the latest information

until the demand command clear is sent.

Bit

Address

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

n+2

Demand

Command

[4000h]

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

n+3

Data 0

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

n+4

Data 1

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

n+5

Data 2

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

R

ea

di

ng

o

f A

la

rm

-is

su

ed

A

xi

s N

um

be

r

n+6

Data 3

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0


PLC Input (Address n is the input and output top address for MSEP.)

Bit

Address

b15 b14 b13 b12 b11 b10 b9

b8

b7

b6

b5

b4 b3 b2 b1

b0

n+2

Response

Command

[4000h]

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

n+3

Data 0

[0]

n+4

Data 1

[Alarm-issued

Axis Number]

1: Alarm

2: Normal

St

at

us

o

f 7

th

A

xi

s

St

at

us

o

f 6

th

A

xi

s

St

at

us

o

f 5

th

A

xi

s

St

at

us

o

f 4

th

A

xi

s

St

at

us

o

f 3

rd

A

xi

s

St

at

us

o

f 2

nd

A

xi

s

St

at

us

o

f 1

st

A

xi

s

St

at

us

o

f 0

th

A

xi

s

n+5

Data 2

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

R

ea

di

ng

o

f A

la

rm

-is

su

ed

A

xi

s N

um

be

r

n+6

Data 3

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0


1 word = 16 bit

1 word = 16 bit