Small system controller – Grass Valley 4300 Krystal Reference Manual v.3.1 User Manual
Page 26

1-14
Krystal 4300 Reference
Section 1 — System Overview
Small System Controller
Older Krystal systems may have been configured with a Small System Con-
troller frame.
The Krystal Small System Controller frame is for multi-channel Krystal
systems of up to four channels. The Small System Controller frame contains
control modules used to manage the resources in the pool, and can contain
optional combiner modules used to join two channels of processed video
into a single video/key output stream.
The Small System Controller is a seven rack unit frame intended to be
mounted in a standard 19 inch equipment rack. The frame holds large
modules installed horizontally from the front (
), and smaller I/
O modules installed horizontally from the back (
Figure 1-13. Small System Controller Frame, Rear View
Figure 1-14. Small System Controller Frame, Front View
POWER
SERIAL
PORTS
GPI
J5
J4
INPUT
VIDEO
KEY/
DEPTH
J3
OUTPUT
J2
J1
MANAGER
J6
EFFECTS
SERIAL
PORTS
EDITOR
EDITOR
SWITCHER
SWITCHER
AUX
AUX
GPI
J5
J4
INPUT
J3
OUTPUT
J2
J1
MANAGER
GRAPHICS
GRAPHICS
J6
EFFECTS
I
0
RESOURCE
MANAGER
J9
J1
J2
J3
J4
J5
J6
J7
J8
VP COMM
J10
J11
CP COMM
J12
J5
50HZ
ANALOG REF IN
60HZ
ANALOG REF IN
VP PARAMETERS
ROUTER
DIAGNOSTICS
J1
J2
A
J3
J4
COMBINER
INPUTS
J6
J7
COMBINER
OUTPUTS
VIDEO
KEY/
DEPTH
B
B BKGND
A BKGND
VIDEO
KEY/
DEPTH
J3
J1
J2
A
J4
J5
VIDEO
KEY/
DEPTH
B
TALLY RECEIVER
TALLY DRIVER
Slot 1
Slot 5
Cooling
Exhaust
Earth Ground
Lug
Controller
I/O Modules
Cooling
Intake
AC Power Switch
and Line Cord
0600-07
Slot ... Module
1 ........ Effect Manager 1 I/O
2 ........ Effect Manager 2 I/O Option
3 ........ Resource Manager I/O
4 ........ 2 x 2 Combiner Inputs Option
5 ........ 2 x 2 Combiner Outputs Option
POWER
DC
EFFECTS
MANAGER
I/O
EFFECTS
MANAGER
I/O
RESOURCE
MANAGER
I/O
BATT
SW
RESET
SW
DS 1
DS 2
DS 3
BATT
SW
RESET
SW
RESET
SW
DS 1
DS 2
DS 3
RST
TMP
LED1
LED2
TX1
RX1
TX2
RX2
TX3
RX3
COL
RCV
JAB
PRT
ERR
VP
PARAM
50HZ
60HZ
+5
+12
-12
2 X 2
COMBINER
RST
RS485
TX
CH 1
TAXI
RS485
RX
CH2
TAXI
DIAG
Fuses
Controller
Modules
Power
Supply
DC Power
Switch
Slot 1
Slot 5
Front Door
Removed
0600-06
Effect Manager CPU
Reset Buttons
Combiner CPU
Reset Button
Resource Manager
Reset Button
RAM
Battery
Switch
Slot ... Module
1 ........ Effect Manager 1 CPU
- Graphics Option
2 ........ Effect Manager 2 CPU Option
- Graphics Option
3 ........ Resource Manager CPU
4 ........ 2 x 2 Combiner CPU Option
5 ........ vacant