beautypg.com

Inj-a – TeeJet Legacy 6000 CAN Guide User Manual

Page 188

background image

A-4

Appendix A - PCM Favorites Settings

Fieldware for The Legacy 6000

Software Version 2.11

INJ-A

Favorite:

INJ-A

Application

Liquid

Application name

INJECTION_PUMP

Configuration

Standard

PCM link

None

Drive Type

Injection

Units

fl oz/ac

Control Basis

Area

Primary Sensor

Injection

Input

A

Sensor Name

INJECTION_PUMP

Calibration #

6.67 pul/fl oz

Cal# Basis

NONE

Secondary Sensor

None

Monitor 1

Product Detect

Input

C

Sensor Name

PUMP_N_FLOW_SENSOR

Alarm Status

Low

Alarm Delay

5 s

Monitor 2

None

Monitor 3

None

Monitor 4

None