TeeJet 801 flowmeter User Manual
Installation
www.teejet.com
INSTALLATION
Please read before installing this equipment. Failure to do so may void your warranty.
Installation
The 801 flow meter gives the best accuracy when there is a smooth, unobstructed
flow through it. To minimize turbulance, there should be at least twelve inches of
straight plumbing upstream from the flow meter and at least 6 inches of straight
plumbing downstream from the flow meter. Mount the flow meter in a location that
physically protects it from damage and allows liquid to drain away after the sprayer is
flushed and secured at the end of the operating day. A straight, vertical section of the
main boom supply line is the ideal location for the flow meter.
Keep the flow meter from lying in a low section of the sprayer plumbing. This is
particularly important in cold weather when water might freeze in the flow meter and
cause damage to the unit. It is also important when applying chemical suspensions
which may settle out and stall the flow meter turbine if they cannot drain away.
Before installing the flow meter insert, make sure there are no obstructions in the
insert cavity. Clearance at the bottom of the cavity is very close and over tightening
or compressing of foreign material in the cavity can cause damage to the flow meter
body. Turn the insert in until it is hand tight.
Prior to each day’s spraying, the flow meter should be inspected to ensure there are
no leaks around the attachment fittings. At the end of the day, care should be taken
to thoroughly flush the flow meter with clean water.
Make sure no water or sediment is trapped in the flow meter
The impeller type flow meters supplied by TeeJet Technologies are inherently rugged.
However, continued use over time will eventually wear the internal bearings and
shafts until the meter becomes inaccurate. Replacement kits are available to repair
the flow meters. Contact your TeeJet Technologies dealer for these parts.
8 0 1 f L O w m e T e r
INSTALLATION, SpecIfIcATION, ANd wArrANTy INfOrmATION
8 0 1 F L O W M E T E R
TeeJet
TeeJet
O-RING
BOLT
HOSE
BARB
FLOW METER
SENSOR
MAIN
FLOW METER
BODY
FLANGED
CLAMP
Flow Meter
Insert
Main Flow
Meter Body
Flanged
Clamp
Bolt
O-Ring
Hose
Barb
Tee
Jet
>12 inches
> 6 inches
MAIN PRODUCT
PUMP
BYPASS LINE
AUTO RANGE
VALVE
R
PUMP DISCHARGE
FLOW METER
TO BOOMS
NOTE: The flow meter must be
mounted to that it will drain
completely when the sprayer
is not operating.
Bypass Line
Main Product
Pump
Pump Discharge
Flow Meter
>12 inches
Auto Range®
Valve
>6 inches
To Booms
NOTE: The Flow
Meter must be mounted
so that it will drain
completely when the
sprayer is not operating
Housing, Deutsch 3 Pos/Skts
Pin Out
Color
Function
A
Red
+12V
B
White
Signal
C
Black
Ground
Sensor