Product setup detailed description, Table 3-5: product setup item descriptions, Product setup detailed description -36 – TeeJet Legacy 6000 CAN Guide User Manual
Page 106

3-36
Chapter 3 - Real-time Setup
Product Setup
Fieldware for the Legacy 6000
Software Version 2.11
Product Setup Detailed Description
Setup Item
Description
In Use
Defines whether the currently selected PCM is used in product application.
Choose Yes or No.
Prescription
If doing Variable Rate product application, select the prescription file (.ARM)
that contains the prescription information for that PCM. The (.ARM) file must be
on the root of the PC card, and the PC card must be inserted into the Legacy
6000 console. If not doing variable rate, then leave this setting at
Layer
Some prescription files (.ARM) can contain several products in a single file. A
single product is associated to a single PCM. In a multiple product prescription
file it is necessary to set which product layer is associated with the currently
selected PCM. If there is only one product layer in the (.ARM) file, this setup
item is automatically set to layer 1 and this page is skipped in the Product
Setup wizard process.
Product
Product Setup contains a product data base containing approximately 4000
product names and their associated EPA number. A product name can be
selected from this setup page. If using a prescription map (.ARM), product
setup automatically extracts the product name from the (.ARM) product layer.
In the Product page select
Product Density
The density of the product being applied. For NH3 applications (See “Appendix
C - NH3 Application” on page C-1.)
Calibration
If this is a new job the calibration number is retrieved from the PCM. You can
change the calibration number here if desired. When starting ARM, this cal
number is compared to the cal number in the PCM. If they are different you will
be prompted to select which cal number to operate with.
Initial Quantity
The initial quantity in the tank/bin/hopper. The ARM software keeps track of the
amount of product remaining and displays this in the Real-time Products page.
Rates A - E
The ARM software allows 5 preset application rates to be selected. These
rates can be accessed in the Real-time page and over-ride the current rate.
Table 3-5: Product Setup Item Descriptions