Chapter 2 Operations
72
(1) Selection of initial device No. and Table No.
Select Controller, Ex Motion Control Board (X), and then CamTable (T).
Figure 2.4.9 Menu (CAM Table Selection)
(2) Selection of device No. and table No. to be created
Figure 2.4.10 Device/CAM Table No. Selection
Click the OK button to open the CAM Table window.
Figure 2.4.11 Setting Window
Select the extension motion control board number.
The first extension motion control board from the left side
of the expansion slot is device No. 0 and the second is
device No. 1.
Specify electronic CAM table numbers as a range. The
maximum CAM table number is set to the value specified
by extension motion control board common parameter No.
2 electronic CAM data table area assignment.
Default value: 0 to 31 tables.
After making the setting, click the OK button.