Chapter 1 installation and w iring 17, Xy z, Model table – IAI America XSEL-S User Manual
Page 25
Chapter 1 Installation and W
iring
17
1.2.3 How to Read Model Nameplate
1.2.4 How to Read Model Number (XSEL-P/Q Type)
*1 A type that allows configuring safety protection circuits with separate motor drive
*2 The RSC2-R**7 series, RCS-RB75 series, RCS-G20, RCS-R*, and linear motor actuator (other
than LAS-N10 and N15) cannot be connected to axes 5 and 6.
*3 A single axis of a large and high-thrust linear actuator (W21HƑ) uses space for 2 axes. Pay
attention to the total number of axes.
*4 Values in column [3] indicate the number of connected axes, regardless of *3.
*5 S indicates adding expansion I/O later without using it from the beginning. In this case,
expansion I/O base becomes empty slot.
Model
Serial number
XSEL – P 㧙 3 㧙 400A 㧙 200ACL 㧙 60ABL 㧙 DV 㧙 N1 㧙 MCEE 㧙 2 㧙 3
X
Y
Z
[
(Axis 1)
[
(Axis 2)
[
(Axis 3)
\
]
^
_
`
Model table
[
Details of axis 1 to axis 6*
2
,
*
3
^
Expansion I/O slots
X
Series
name
Y
Controller
type
Z
*
4
Number
of axes
Motor
Output
Encoder
type
Brake Creep
High Accel/
Decel Specifi-
cations
Home
Sensor
(LS)
Synchro-
nization
Desig-
nation
\
Network
(Dedicated
Slot)
]
Standard I/O
(Slot 1)
Slot 2
Slot 3
Slot 4
_
I/O Flat
cable
length
`
Power-
supply
voltage
E
(Not used)
E
(Not used)
E
(Not used)
E
(Not used)
N1
Input 32/
output 16
NPN board
N1
Expansion I/O
NPN32/16
N1
Expansion I/O
NPN32/16
N1
Expansion I/O
NPN32/16
N2
Input 16/
output 32
NPN board
N2
Expansion I/O
NPN16/32
N2
Expansion I/O
NPN16/32
N2
Expansion I/O
NPN16/32
N3
Input 48/
output 48
PNP board
N3
Multipoint I/O
NPN48/48
N3
Multipoint I/O
NPN48/48
N3
Multipoint I/O
NPN48/48
P1
Input 32/
output 16
NPN board
P1
Expansion I/O
PNP32/16
P1
Expansion I/O
PNP32/16
P1
Expansion I/O
PNP32/16
P2
Input 16/
output 32
NPN board
P2
Expansion I/O
PNP16/32
P2
Expansion I/O
PNP16/32
P2
Expansion I/O
PNP16/32
P3
Input 48/
output 48
PNP board
P3
Multipoint I/O
PNP48/48
P3
Multipoint I/O
PNP48/48
P3
Multipoint I/O
PNP48/48
S
*5
With
expansion
I/O base
S
*5
With
expansion
I/O base
S
*5
With
expansion
I/O base
XSEL
P
(Standard)
Q
(Complying
with
Safety
Category)
1
(1-axis)
2
(2-axis)
3
(3-axis)
4
(4-axis)
5
(5-axis)
6
(6-axis)
20
(20W)
30D
(30W for RSC2)
30R
(30W for RS)
60
(60W)
100
(100W)
150
(150W)
200
(200W)
300
(300W)
400
(400W)
600
(600W)
750
(750W)
1000
(
1000W
)
I
(Incremental)
A
(Absolute)
Not
Specified
(Without
brake)
B
(With
brake)
Not
Specified
(Without
creep)
C
(With
creep)
Not
Specified
(Standard
type)
HA
(High Accel/
Decel type)
Not
Specified
(Without
home
sensor)
L
(With
home
sensor)
Not
Specified
(No
synchro-
nization)
M
(Master-
axis
desig-
nation)
S
(Slave-
axis
desig-
nation)
Not
Specified
(Without
network)
DV
DeviceNet
256/256
board
CC
CC-Link
256/256
board
PR
PROFIBUS
256/256
board
ET
Ethernet
Data
communicati
on board
MC
Extension motion
control board
MC
Extension motion
control board
MC
Extension motion
control board
2 : 2m
(Standard)
3 : 3m
5 : 5m
0 : None
(*1)
2
(Single-
phase
200V)
3
(3-phase
200V)