Chapter 2 Operations

42

2.3 Parameter Settings on the XSEL controller Side and Checking Procedures

Set the following parameters and check if they are properly set.

Item

Parameter

No.

Parameter name

Importance of setting

A: Mandatory (function selection)

B: Mandatory (depending on usage)

C: Check (set as required)

529

Axis pattern selection for the extension motion control board

synchronizing main CPU control main axis

B

530

Extension motion control board position data count

B

531

Maximum axis number for extension motion control board

position data definition

B

532

Position data count for extension motion control board position

data definition

B

533

Extension motion control board synchronized main CPU control

master axis position type

C

I/O parameter

534~581

Extension motion control board axis * control attribute

Extension motion control board axis * control I/O port top No.

Extension motion control board axis * control I/O port top No.

B

166

Specification of drive disabled axis

C

167

Slave operation command origin unit type

C

Parameter for each axis

168

Slave operation command origin device No.

C

2

Electronic CAM table area assignment

C

3

Minimum emergency deceleration speed

C

Extension motion control

board common

parameters

4

Maximum jog speed at home return not completed

C

1

Channel usage method

A

Extension motion control

board input channel

parameters

2

Pulse input mode

C

1

Channel usage method

A

2

Pulse output mode

A

3

Pulse output mode polarity

A

5

Encoder pulse count per rotation

A

6

Screw lead

B

7

Software limit +

B

8

Software limit –

B

9

Software limit margin

B

10

Electronic gear numerator

B

11

Electronic gear denominator

B

12

Maximum speed

B

13

Maximum acceleration speed

B

14

Maximum deceleration speed

B

15

Deceleration speed at synchronous movement completion

B

16

VLMX speed

B

Extension motion control

board output channel

parameters

18

Control device No.

C

Caution

(1) Enable Switch

If the effective axis pattern of the all-axis parameter No. 9 “enable switch (deadman switch/safety gate)

effective physical axis pattern” is set to a value other than 11111111B (only specific main CPU control axes are

enabled), axes of the extension motion control board are not stopped by the enable switch.

(2) Connection Recovery Types

When a extension motion control board is installed, it is not allowed to use miscellaneous parameter No. 10

“emergency stop recovery type” or miscellaneous parameter No. 11 “enable switch (deadman switch/enable

switch) recovery type” by setting “2” (recovery while continuing operation). The error No. 506 "Emergency

stop/enable switch recovery type parameter error” occurs when such settings are made.

(3) Do not change I/O parameter No. 20 “input filtering” cycle for extension motion control board axis control input

ports. They may not be able to operate normally if the cycle is changed.