1 supported versions, 2 setting extension motion control board window – IAI America XSEL-S User Manual
Page 183

Chapter 6 Operations of X-SEL
PC Software Extension Motion Control Functions
175
Chapter 6 Operations of X-SEL PC Software Extension Motion Control
Functions
6.1 Supported Versions
IA-101-X-MW
Ver.8.1.0.0~
IA-101-X-USBMW
Ver.8.1.0.0~
IA-101-XA-MW
Ver.8.1.0.0~
6.2 Setting Extension Motion Control Board Window
On this window, it is possible to edit, transfer, save, and print CAM tables and parameters for
extension motion control boards.
Explanation of Items on the Setting Extension Motion Control Board Window
(1) Select [Controller] o [Ex Motion Control Board (X)] o [CAM Table (T)] from the menu (Figure 2.1).
(The Setting Extension Motion Control Board window can be opened by clicking [Controller] o [Ex
Motion Control Board (X)] o [Parameter (P)].)
Figure 2.1. Menu (Setting Extension Motion Control Board)
(2) The Select Dev/Table No. dialog box (Figure 2.2) appears. Select device No. and Table No. you want
to use and click [OK]. (If you select [Parameter (P)] in the menu, you can only select device No.
(Figure 1.3).)
Device No. refers to the ordinal number of an I/O slot on the controller where a extension motion
control board is installed, counting from the leftmost slot.
Example: If boards are installed on standard I/O slot and expansion I/O slot 2:
Device No. of the extension motion control board installed on the standard I/O slot is 0.
Device No. of the extension motion control board installed on expansion I/O slot 2 is 1.
Figure 2.2. Select Dev/Table No.
(When [CAM Table (T)] is selected in the menu)
Figure 2.2. Select Dev/Table No.
(When [Parameter (P)] is selected in the menu)