beautypg.com

IAI America XSEL-S User Manual

Page 72

background image

Chapter 2 Operations

64

2.4.2 Synchronized Electronic CAM Operation

A slave axis operates according to the CAM tables while synchronizing to the specified master axis.

(1) Synchronous movement type

It is possible to select either “immediate start” or “start at master axis arriving at specified position” as

synchronous start type. The setting is made using the XCAS (expansion motion board axis

synchronization electronic CAM (master axis specification) synchronization start) command.

[1] Immediate start

Start synchronization by setting the current master axis position as the base point (phase = 0).

[2] Start at master axis arriving at specified position

Start synchronization from the time when the master axis arrives at the specified position, by

setting the position as the base point (phase = 0).

-1 cycle

+1 cycle

Current position

Current position - stroke

Current position + stroke

-1 cycle

+1 cycle

Current position

Specified

position

Current position - stroke

Current position + stroke