Chapter 2 Operations

43

2.3.1 Parameter Settings on the X-SEL Main Side

Use the PC Software for X-SEL (IA-101-X-MW for RS232C, IA-101-X-USBMV for USB) to set the

parameters following the procedure below.

(1) I/O parameter setting

Set the control I/O port assignment of RC controller and position data count for extension motion

control board axis that are controlled on the pulse I/O board.

x

Display of the I/O parameter setting window

Start the PC Software for X-SEL and click Parameter and then Edit.

Figure 2.2.1 Menu (at Selecting Parameter – Edit)

x

The Edit Parameter window appears.

Figure 2.2.2 Edit Parameter Window

[1] Axis pattern selection for the extension motion control board synchronizing main CPU control

main axis (I/O parameter No. 529): The number of main CPU axes which can be used for the

synchronous operation, such as the electronic CAM, is up to six. This parameter selects the

main CPU control axis which can be specified as the synchronous main axes. (Only XSEL-R/S

has this function).

Defaul:

00111111B (From first to sixth axes can be specified as synchronous main axes).

Set Value: Each Bit = 1 (Specification of the extension motion control board synchronizing main

axis available)

Each Bit = 0 (Specification of the extension motion control board synchronizing main

axis unavailable)

This manual is related to the following products: