beautypg.com

IAI America XSEL-S User Manual

Page 192

background image

Chapter 6 Operations of X-SEL

PC Software Extension Motion Control Functions

184

[4] Displacement

Figure 2.17. Displacement

Phase

Phase values of each displacement data are displayed in this column.

Displacement

Displacement of slave axes in this column is set.

* Displacement at phase 0 is always 0, which cannot be changed.

[5] CAM curve graph

Section definition data/displacement data are displayed in graphs.

Up to 8 tables selected from the CAM curve display settings are displayed.

Figure 2.18. CAM Curve Graph

(No 100% Display Setting)

Figure 2.19. CAM Curve Graph

(100% Display Setting for both Phase

and Displacement)