IAI America XSEL-S User Manual
Page 148

Chapter 4 Parameters
140
4.1.3 Extension Motion Control Board Common Parameters
No.
Parameter name
Unit
Input range Default value
(reference)
Reference section
1 (For extension)
0H~FFFFFFFFH 00000000H
-
2 Electronic CAM table area
assignment
0H~FFFFFFFFH 32013201H
4.2 [7]
3 Minimum emergency deceleration 0.01G
1~999
30
4.2 [8]
4 Maximum jog speed when home
return is not completed
mm/s
1~250
30
4.2 [9]
5 Reserved by system
0~9
0
-
6 to
20 (For extension)
0H~FFFFFFFFH 00000000H
-
21 Reserved by system
0H~FFFFFFFFH 00000000H
-
22 Reserved by system
0H~FFFFFFFFH 00000000H
-
23 to
30 (For extension)
0H~FFFFFFFFH 00000000H
-
31 Reserved by system
1~999999
20000
-
32 Reserved by system
0~999999
10000
-
33 Reserved by system
1~2000
700
-
34 Reserved by system
1~5
1
-
35 Reserved by system
-10~7
-4
-
36 Reserved by system
0~99999999
100
-
37 Reserved by system
1~100
10
-
38 Reserved by system
0~50000
10000
-
39 to
100 (For extension)
0H~FFFFFFFFH 00000000H
-