beautypg.com

IAI America XSEL-S User Manual

Page 178

background image

Chapter 5 Handling Errors

170

5.2.4 Errors Related to Extension Motion Control Boards (Cold Start Cancellation Level)

Level

No.

Error name

Description/Action

Cold start

500 Slave board flash ROM write error

Writing to the flash ROM of a slave board failed. Failure of

slave board and similar can be the cause. Check the installed

slave boards.

Cold start

501 Slave board flash ROM write completion

check timeout error

Completion of writing to the flash ROM of a slave board could

not be confirmed. Failure of slave board and similar can be the

cause. Check the installed slave boards. Moreover, this error

can occur when error No. 6BE, 6BF, 6C0, 6C4, 6C5, etc. occur

at the same time.

Cold start

502 Slave transmission data generation logic error Slave transmission data generation error

Cold start

503 Extension motion control board ready check

timeout error

Normal startup of boards could not be confirmed. Check

installed extension motion control boards.

Cold start

504 Extension motion control board target

information initialization error

Initialization sequence of extension motion control board

information was not normally completed. Check installed

extension motion control boards.

Cold start

505 Extension motion control board axis control

I/O port assignment parameter error

Setting values of parameters related to extension motion

control board axis control I/O port assignment are invalid.

Check I/O parameter Nos. 534 to 581 for invalid port No.,

duplicated specification with other system I/O ports and so on.

Cold start

506 Emergency stop/enable switch recovery type

parameter error

Setting values of emergency stop/enable switch recovery type

parameters are invalid. If extension motion control boards are

installed, it is not allowed to specify to recover while continuing

movement. Check miscellaneous parameters No. 10 and 11.

Cold start

507 Extension motion control board axis position

data setting error

Position data settings for extension motion control board axes

are invalid. Check I/O parameters No. 530, 531, and 532.

Cold start

508 Extension motion control board axis position

data valid address error

It is attempted to access valid position data of extension

motion control board axes.

Cold start

509 Extension motion control board DPRAM

access right timeout error

Unable to acquire DPRAM access right for a specified time or

longer.

Cold start

50A Extension motion control board DPRAM

access logic error (main CPU detection)

An error in DPRAM access right control was detected.

Cold start

50B Extension motion control board non-definition

DPRAM format ID error (main CPU detection)

An error occurred during controller internal communication.

The following causes can be considered:

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and board

application area firmware version are not consistent (wrong

combination).

Cold start

50C Extension motion control board DPRAM data

sum check error (main CPU detection)

A DPRAM data sum check error was detected. Failures of

extension motion control boards, etc. can be considered to be

the cause. Check installed extension motion control boards.

Cold start

50D Extension motion control board fatal failure

error

A fatal failure error occurred in extension motion control boards

(SLVALM).

Cold start

50E Extension motion control board CPU ready

OFF error

CPU ready of extension motion control boards was turned off.

Cold start

50F

Extension motion control board slave CPU

servo underrun detection error (main CPU

detection)

A servo control underrun error was detected in extension

motion control boards. It is necessary to turn the power supply

on again.

Cold start

510 Extension motion control board error

An error occurred in extension motion control boards. This

error occurs if the main CPU board software does not support

error codes of extension motion control boards. Take actions

according to the error list.

x

If Info.2 of the error list is 76h:

The same error as error No. 49A occurred in extension

motion control boards. Refer to the item explaining the

corresponding error No.

In other cases, contact us and report the description of the

error list.

This manual is related to the following products: