beautypg.com

9 environmental characteristics – AMETEK ReFlex User Manual

Page 99

background image

AC Power Supplies

ReFlex Power™

4-14

M380056-01 Rev K

4.3.9

E

NVIRONMENTAL

C

HARACTERISTICS

Operating Temperature

Standard: 0 to 50 °C

Extended Range Option: -10 to 55 °C

Operating Altitude

Standard: 0 to 6,500 ft

Extended Range Option: 0 to 15,000 ft

Operating Humidity

95% non-condensing

Operating Shock

Class 3 MIL-PRF-28800F

Operating Vibration

Class 3 MIL-PRF-28800F

Operation Without Fully Populated Mainframe

If Mainframe is not fully populated with modules, filler panels must be installed
in empty slots to maintain proper airflow and structural integrity.

Non-Operating Temperature

-40 to 71 °C

Non-Operating Altitude

0 to 50,000 ft

Non-Operating Shock

Class 3 MIL-PRF-28800F

Non-Operating Vibration

Class 3 MIL-PRF-28800F