Control interface, 3 mechanical characteristics - overview – AMETEK ReFlex User Manual
Page 31
ReFlex Power™
System Overview
M380056-01 Rev J
1-9
C
ONTROL
I
NTERFACE
The ReFlex Power™ system utilizes a multi-processor command and
control architecture wherein the Controller module and each power
module has an embedded processor. There is a single Ethernet
communication interface to the user host controller through the
Controller module, while all modules comprising the system
communicate through an internal ARCNET bus. The user
communications interface provides direct control using SCPI
commands, and IVI-compatible drivers.
1.3.3
M
ECHANICAL
C
HARACTERISTICS
-
O
VERVIEW
The ReFlex Power™ system has a modular configuration wherein
modules plug into a backplane of the Mainframe. The Mainframe
assembly provides an enclosure and functional services for the various
assets.
Table 1-2. Asset Physical Characteristics
Asset
Type
Size
Weight
RFP-D1016-021-xxxx Low-power DC module
1.4” H x 6.75”H x 15”D 4.5 lb
RFP-D1065-5A1-xxxx Low-power DC module
1.4” H x 6.75”H x 15”D 4.5 lb
RFP-D2033-030-xxxx High-power DC module
2.8” H x 6.75”H x 15”D 9.0 lb
RFP-D2050-020-xxxx High-power DC module
2.8” H x 6.75”H x 15”D 9.0 lb
RFP-D2050-025-xxxx High-power DC module
2.8” H x 6.75”H x 15”D 9.0 lb
RFP-D2120-8A3-xxxx High-power DC module
2.8” H x 6.75”H x 15”D 9.0 lb
RFP-D2450-2A3-xxxx High-power DC module
2.8” H x 6.75”H x 15”D 9.0 lb
RFP-A30XK-875-xxxx AC power module
4.2” H x 6.75”H x 15”D 11.4 lb
RFP-L3500-750-xxxx High-power active load
4.2” H x 6.75”H x 15”D 12.9 lb
RFP-L3500-375-xxxx Low-power active load
4.2” H x 6.75”H x 15”D 8.2 lb
RFP-F1000-001-xxxx Fixed-power DC module
1.4” H x 6.75”H x 15”D 4.7 lb
RFP-C1LAN-000-xxxx Controller module
1.4” H x 6.75”H x 15”D 2.4 lb
RFP-M000-xxx-xxxx
Enclosure
7” H x 19”H x 17”D
11.6 lb
Mounting Provisions:
Front panel mounting flanges and chassis hole pattern for RETMA rack slides or
rails
Color:
Mainframe: Gold color chem-film per Elgar specification 1005019-01
Modules: Black; color number 27038 per FED-STD-595
Cooling Provisions
No Mainframe cooling fans; all fans are incorporated into the
individual power modules; front and rear must be unobstructed so that
air flow is not impeded