AC Power Supplies

ReFlex Power™

4-84

M380056-01 Rev K

CAL:OUTP:FREQ:CURR7

26. Perform the voltage calibration:

CAL:OUTP:FREQ:CALC

27. Send the system error query command to make sure calibration was successful:

SYST:ERR?

28. If there is no error returned at the system error query command then save the

calibration data

CAL:UNLOCK “6867”

CAL:STORE

CAL:LOCK

29. Reset the unit

*RST

This manual is related to the following products: