1 product matrix, 2 input characteristics, Input voltage – AMETEK ReFlex User Manual
Page 39: Input current, Input voltage sag/surge
Mainframe
ReFlex Power™
2-4
M380056-01 Rev J
2.3.1
P
RODUCT
M
ATRIX
Model
Number of Slots
Maximum Aggregate Output
Power
Enclosure
Mainframe
12
6,000W
Rack-mount, 4U
Module
Model
Voltage
Full-Scale
Rating
Current
Full-Scale Rating
Power Rating Module Width
RFP-D1016-021-xxxx
16VDC
20.6A
330W
Single, 1.4”
RFP-D1065-5A1-xxxx
65VDC
5.1A
332W
Single, 1.4”
RFP-D2033-030-xxxx
33VDC
30A
990W
Double, 2.8”
RFP-D2050-020-xxxx
50VDC
20A
1000W
Double, 2.8”
RFP-D2050-025-xxxx
50VDC
25A
1250W
Double, 2.8”
RFP-D2120-8A3-xxxx
120VDC
8.3A
996W
Double, 2.8”
RFP-D2450-2A3-xxxx
450VDC
2.3A
1,035W
Double, 2.8”
RFP-A30XK-875-xxxx 140/280VAC
7/3.5A
875W
Triple, 4.2”
RFP-L3500-750-xxxx
500VDC
30A
750W
Triple, 4.2”
RFP-L3500-375-xxxx
500VDC
15A
375W
Triple, 4.2”
RFP-F1000-001-xxxx
5V/-5VDC
15/-15VDC
10/5A
3/3A
165W
Single, 1.4”
RFP-C1LAN-000-xxxx
-
-
-
Single, 1.4”
2.3.2
I
NPUT
C
HARACTERISTICS
I
NPUT
V
OLTAGE
1-phase: 100/115/120/200/208/230V
3-phase: 200/208V, delta, 3-wire plus ground
115/200V or 120/208V wye, 4-wire plus ground
230/400V, wye, 4-wire plus ground
DC Input: 270VDC
I
NPUT
V
OLTAGE
O
PERATING
R
ANGE
(input line to return voltage)
AC Input: 85-264VAC;
DC Input: 210-300VDC
I
NPUT
C
URRENT
Sum of the input currents of the individual modules installed.
Maximum allowed current per line, 24A
I
NPUT
V
OLTAGE
S
AG
/S
URGE
With AC input: sag to 65% of nominal at 208VAC and 230VAC input for 450ms;
surge to 135% of nominal at 208VAC and 230VAC input for 450ms
With DC input: 314VDC, maximum for 2s; 364.5VDC, maximum for 450ms