7 dac offset calibration for voltage range high – AMETEK ReFlex User Manual
Page 137

AC Power Supplies
ReFlex Power™
4-52
M380056-01 Rev K
4.6.7
DAC
O
FFSET
C
ALIBRATION FOR
V
OLTAGE
R
ANGE
H
IGH
This procedure calibrates the voltage DAC of the power supply.
1. Connect the meter between the output and the output return lead.
2. Set the voltmeter to read the DC voltage.
3. Ensure that no load is connected to the output.
4. Issue clear and reset commands:
*CLS
*RST
5. Set the voltage range of the power supply to high
SOUR
6. Set the OVP supervisory to limit 12000
CAL
7. Set the OCP supervisory to maximum limit.
CAL
8. Set the voltage to zero
CAL
9. Set the current to maximum limit
CAL
10. DAC range is from 0 to 65535. Therefore set the DAC at the middle of the range
CAL
11. Turn the unit on
OUTP
12. Set the DC loop off
CAL
13. Program the DAC to 0.5% below the middle range
CAL