AC Power Supplies

ReFlex Power™

4-52

M380056-01 Rev K

4.6.7

DAC

O

FFSET

C

ALIBRATION FOR

V

OLTAGE

R

ANGE

H

IGH

This procedure calibrates the voltage DAC of the power supply.

1. Connect the meter between the output and the output return lead.

2. Set the voltmeter to read the DC voltage.

3. Ensure that no load is connected to the output.

4. Issue clear and reset commands:

*CLS
*RST

5. Set the voltage range of the power supply to high

SOUR:VOLT:RANGE 1

6. Set the OVP supervisory to limit 12000

CAL:OUTP:VOLT:PROT:COUNTS 12000

7. Set the OCP supervisory to maximum limit.

CAL:OUTP:CURR:PROT:COUNTS 4000

8. Set the voltage to zero

CAL:OUTP:VOLT:COUNTS 0

9. Set the current to maximum limit

CAL:OUTP:CURR:COUNTS 4000

10. DAC range is from 0 to 65535. Therefore set the DAC at the middle of the range

CAL:OUTP:DAC:COUNTS 32768

11. Turn the unit on

OUTP:STATE 1

12. Set the DC loop off

CAL:OUTP:DCLOOP OFF

13. Program the DAC to 0.5% below the middle range

CAL:OUTP:DAC:COUNTS 32456

This manual is related to the following products: