Active Loads

M380056-01 Rev J

7-7

7.2.4

P

ROGRAMMABLE

F

UNCTIONS

The Active Load module can be programmed several variables:

Input Current

Resistance

Over Power Protection

Over Voltage Protection

Over Current Protection

7.2.5

R

EADBACK

F

UNCTIONS

Input Current

Input Voltage

Power

Over Power Protection value

Over Voltage Protection value

Over Current Protection value

7.3

SPECIFICATIONS

All specifications are valid after a 30-minute warm-up. Modules could be used at
reduced accuracy immediately following power-on. All accuracy specifications
are plus/minus variations around the nominal parameter values, unless otherwise
noted. Unless otherwise specified, requirements apply at the front panel output
terminals, over the entire programming range, and with remote sense connected
to front panel terminals. Performance specifications are valid following calibration
at 25 °C, +/- 5 °C

7.3.1

P

RODUCT

M

ATRIX

Model

Voltage

Full-Scale

Rating

Current

Full-Scale

Rating

Power Rating

Module Width

HPAL

500V

30A

750W

Triple, 4.2”

LPAL

500V

15A

375W

Triple, 4.2”