beautypg.com

4 module installation – AMETEK ReFlex User Manual

Page 45

background image

Mainframe

ReFlex Power™

2-10

M380056-01 Rev J

2.4.4

M

ODULE

I

NSTALLATION

CAUTION
Modules and the Mainframe contain ESD sensitive circuitry.
Follow appropriate handling and grounding procedures to prevent
damage to a module or Mainframe. Modules and Mainframe
should be handled by the enclosure, with care to protect the
connectors from ESD discharges.

CAUTION
Input power must be disconnected to the Mainframe before
a module is inserted or extracted. Inserting or extracting a
module with power installed (hot-swapping) could result in
damage to the module or Mainframe. Prior to turning power
on, ensure that front panel captive thumbscrews are
tightened.

Modules are installed into the Mainframe from the front of the chassis. Refer to
Figure 2-3 for the orientation of a module and Mainframe during installation.

1. Ensure that the AC/DC input power is disconnected before

installing or removing any module(s).

2. Insert the module into the mainframe, rear panel first, aligning the

module guide rails the top and bottom Mainframe guides.

3. Gently slide the module completely into the mainframe until the

guide pins of the module rear connector engage the mating
backplane connector.

4. Fully seat the module until the front panel inner surface is snug

against the mainframe chassis.

5. Secure the module(s) to the Mainframe at the top and bottom of

each front panel by turning the captive thumbscrews clockwise
using a flat head screwdriver to a maximum torque of 20 in-lb.

6. Install a filler panel over any empty slot, and secure in place at the

top and bottom by turning the captive thumbscrews clockwise
using a flat head screwdriver to a maximum torque of 20 in-lb.

This manual is related to the following products: