AMETEK ReFlex User Manual
Page 49
Mainframe
ReFlex Power™
2-14
M380056-01 Rev J
Table 2-1. Input Power Allocation
Input
Service
Phases
Input
Designation
Input
Connector
Pin
Input Service
Connection
Slot
Supplied
100/115/120VAC
200/208VAC
220/230/240VAC
1
L1
F
Phase
Slot 1-4
L1-RTN
E
Return
L2
A
Phase
Slot 5-8
L2-RTN
G
Return
L3
B
Phase
Slot 9-12
L3-RTN
C
Return
GND
D
Ground
Slot 1-12
Safety GND Chassis GND
Ground
Chassis
200/208VAC
3,
Delta
L1
F
Phase-A
Slot 1-4
L1-RTN
E
Phase-B
L2
A
Phase-B
Slot 5-8
L2-RTN
G
Phase-C
L3
B
Phase-C
Slot 9-12
L3-RTN
C
Phase-A
GND
D
Ground
Slot 1-12
Safety GND Chassis GND
Ground
Chassis
200/208VAC
220/230/240VAC
3,
Wye
L1
F
Phase-A
Slot 1-4
L1-RTN
E
Neutral
L2
A
Phase-B
Slot 5-8
L2-RTN
G
Neutral
L3
B
Phase-C
Slot 9-12
L3-RTN
C
Neutral
GND
D
Ground
Slot 1-12
Safety GND Chassis GND
Ground
Chassis
210-300VDC
DC
L1
F
Source
Slot 1-4
L1-RTN
E
Return
L2
A
Source
Slot 5-8
L2-RTN
G
Return
L3
B
Source
Slot 9-12
L3-RTN
C
Return
GND
D
Ground
Slot 1-12
Safety GND Chassis GND
Ground
Chassis