4 default operational conditions, Power-on conditions, Reset conditions – AMETEK ReFlex User Manual
Page 124

ReFlex Power™
AC Power Supplies
M380056-01 Rev K
4-39
4.5.4
D
EFAULT
O
PERATIONAL
C
ONDITIONS
P
OWER
-O
N
C
ONDITIONS
When an AC power supply module is first powered on, the following
parameters are set to factory default values:
•
Output configuration: standalone
•
Output voltage: 0V
•
Output current: full scale
•
Overvoltage protection (OVP): 106% of full scale voltage; programmable
mode
•
Undervoltage protection (UVP): 0V, programmable mode
•
Overcurrent protection (OCP): 106% of full scale current; programmable
mode
•
Output state: off
•
Output isolation and remote sense relays: open
•
Frequency set to 60 Hz
R
ESET
C
ONDITIONS
If a module is reset with the SCPI command, *RST[n], (where n is the module
address), the following default conditions are set:
•
Output configuration: unchanged
•
Output voltage: 0V
•
Output current: full scale
•
Overvoltage protection (OVP): 106% of full scale voltage; programmable
mode
•
Undervoltage protection (UVP): 0V, programmable mode
•
Overcurrent protection (OCP): 106% of full scale current; programmable
mode
•
Output state: off
•
Output isolation and remote sense relays: open
•
Frequency set to 60 Hz
•
All status reporting data structures are cleared. Enable-masks are not
cleared.