DC Power Supplies

ReFlex Power™

6-10

M380056-01 Rev K

C

URRENT

L

INE

R

EGULATION

RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:

0.05% of full-scale for 10% line change

RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX,
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:

0.1% of full-scale for 10% line change

C

URRENT

L

OAD

R

EGULATION

0.1% of full-scale for 100% load change

6.3.3

M

EASUREMENT

V

OLTAGE

A

CCURACY

0.1% of set point plus 0.1% of full scale, at 25 °C, +/- 5 °C

V

OLTAGE

R

ESOLUTION

RFP-D1016-021-XXXX:

0.47mV

RFP-D1065-5A1-XXXX:

1.9mV

RFP-D2033-030-XXXX:

2mV

RFP-D2050-020-XXXX:

3mV

RFP-D2050-025-XXXX:

3mV

RFP-D2120-8A3-XXXX:

7mV

RFP-D2450-2A3-XXXX:

28mV

C

URRENT

A

CCURACY

0.1% of full-scale plus 0.2% of set-point, at 25 °C, +/- 5 °C

C

URRENT

R

ESOLUTION

RFP-D1016-021-XXXX:

1.28mA

RFP-D1065-5A1-XXXX:

0.32mA

RFP-D2033-030-XXXX:

1.9mA

RFP-D2050-020-XXXX:

1.3mA

RFP-D2050-025-XXXX:

1.6mA

RFP-D2120-8A3-XXXX:

0.6mA

RFP-D2450-2A3-XXXX:

0.14mA

6.3.4

S

UPERVISORY

C

HARACTERISTICS

O

VERVOLTAGE

(OVP)

The OVP operation is user -selectable to be programmable or tracking. The
default mode of operation is programmable OVP.

Programmable operation: The OVP threshold is programmable
from 5 to 110% of full-scale output voltage.

Tracking operation: The OVP threshold is automatically
adjusted to 110% above the programmed value of the output