beautypg.com

3 installation – AMETEK ReFlex User Manual

Page 289

background image

Active Loads

ReFlex Power™

7-14

M380056-01 Rev J

7.4.3

I

NSTALLATION

CAUTION

The module contains ESD sensitive circuitry. Follow appropriate handling
and grounding procedures to prevent damage to the module. The module
should be handled by the enclosure, with care to protect the connectors
from ESD discharges.

Modules are installed into the Mainframe from the front of the chassis. Refer to
Figure 7-4 for a view showing the orientation of a module and Mainframe during
installation.

1. Ensure that the Mainframe AC/DC input power is disconnected before

installing or removing any module(s).

2. Insert the module into the Mainframe, aligning the guide rails at the rear of

the module with the top and bottom Mainframe guides.

3. Gently slide the module completely into the Mainframe until the guide pins

of the module rear connector engage the mating backplane connector.

4. Fully seat the module until the front panel inner surface is snug against the

Mainframe chassis.

5. Secure the module(s) to the Mainframe at the top and bottom of each front

panel by turning the captive thumb screws clockwise using a flat blade
screwdriver to a maximum torque of 20 in-lb.

6. Install a filler panel over any empty slot, and secure in place at the top and

bottom by turning the captive thumb screws clockwise using a flat blade
screwdriver to a maximum torque of 20 in-lb.

CAUTION

Input power must be disconnected to the Mainframe before a module is
inserted or extracted. Inserting or extracting a module with power
installed (hot-swapping) could result in damage to the module or
Mainframe. Prior to turning power on, ensure that front panel captive
fasteners are tightened

.

This manual is related to the following products: