the heaviest gauge practical to minimize line drop. The remote sense wires
should be twisted, and may need shielding depending on the electrical noise
environment of the application. Figure 5-8 shows a standalone load connection
with remote sensing.
(-)
(-)
(-)
(+)
(+)
(+)
Output
Sense
Input
Load
Power Supply
Twisted-Pair Cable
Twisted-Pair Cable
(shielded if noise present)
Figure 5-8. Each Output Voltage Configuration
5.5.4
D
EFAULT
O
PERATIONAL
C
ONDITIONS
P
OWER
-O
N
C
ONDITIONS
When the FPDC power supply module is first powered on, the following
parameters are set to factory default values:
•
Output configuration: standalone
•
Output voltage: 0V
•
Output isolation and remote sense relays: open
R
ESET
C
ONDITIONS
If a module is reset with the SCPI command, *RST[n], (where n is the module
address), the following default conditions are set:
•
Output configuration: unchanged
•
Output voltage: 0V
•
Output isolation and remote sense relays: open
•
All status reporting data structures are cleared. Enable-masks are not
cleared.