the heaviest gauge practical to minimize line drop. The remote sense wires
should be twisted, and may need shielding depending on the electrical noise
environment of the application. Figure 5-8 shows a standalone load connection
with remote sensing.

(-)

(-)

(-)

(+)

(+)

(+)

Output

Sense

Input

Load

Power Supply

Twisted-Pair Cable

Twisted-Pair Cable
(shielded if noise present)

Figure 5-8. Each Output Voltage Configuration

5.5.4

D

EFAULT

O

PERATIONAL

C

ONDITIONS

P

OWER

-O

N

C

ONDITIONS

When the FPDC power supply module is first powered on, the following
parameters are set to factory default values:

Output configuration: standalone

Output voltage: 0V

Output isolation and remote sense relays: open

R

ESET

C

ONDITIONS

If a module is reset with the SCPI command, *RST[n], (where n is the module
address), the following default conditions are set:

Output configuration: unchanged

Output voltage: 0V

Output isolation and remote sense relays: open

All status reporting data structures are cleared. Enable-masks are not
cleared.