background image

ReFlex Power™ Controller

ReFlex Power™

3-8

M380056-01 Rev J

3.3.6

E

NVIRONMENTAL

C

HARACTERISTICS

O

PERATING

T

EMPERATURE

Standard: 0 to 50 °C

Extended Range Option: -10 to 55 °C

O

PERATING

A

LTITUDE

Standard: 0 to 6,500 ft

Extended Range Option: 0 to 15,000 ft

O

PERATING

H

UMIDITY

95% non-condensing

O

PERATING

S

HOCK

Class 3 MIL-PRF-28800F

O

PERATING

V

IBRATION

Class 3 MIL-PRF-28800F

O

PERATION

W

ITHOUT

F

ULLY

P

OPULATED

M

AINFRAME

If Mainframe is not fully populated with modules, filler panels must be
installed in empty slots to maintain proper airflow and structural integrity.

N

ON

-O

PERATING

T

EMPERATURE

-40 to 71 °C

N

ON

-O

PERATING

A

LTITUDE

0 to 50,000 ft

N

ON

-O

PERATING

S

HOCK

Class 3 MIL-PRF-28800F

N

ON

-O

PERATING

V

IBRATION

Class 3 MIL-PRF-28800F