5 reflex power™ firmware compatibility, Reflex power™ firmware compatibility – AMETEK ReFlex User Manual
Page 35

ReFlex Power™
System Overview
M380056-01 Rev J
1-13
•
User host controller with suitable communications interface
•
Communications software
1.5
REFLEX POWER™ FIRMWARE
COMPATIBILITY
With the release of firmware version 3.000.000 and higher, the controller
firmware revision and the firmware in the power and load modules must be at
the same major revision level. Thus, it is not possible to mix revision
2.000.000 and revision 3.000.000 assets. When powering up a system with
mixed revision assets installed, the red Fault LED will blink on a version 3
controller if a version 2 module is detected. If a version 3 Module detects a
version 2 controller, the Module’s red Fault LED will blink indicating the
firmware miss-match. The *TST? response will also have an error bit set
indicating miss-matched firmware.
RFP version 2 Modules can be upgraded to version 3, and version 3 modules
can be downgraded to version 2.
The Order numbers for version 2 and version 3 Modules are different, contact
Sales for further information.