2 modes of operation, 3 default operational conditions, 4 initial functional tests – AMETEK ReFlex User Manual
Page 82

ReFlex Power™
ReFlex Power™ Controller
M380056-01 Rev J
3-19
6 Power 0n/Off switch: rocker switch for RFPC internal power to the
modules.
7 Lan – Green LED indicates LXI
TM
status.
8 Con – Green LED indicates LAN connectivity.
9 Net – Amber LED indicates LAN network activity.
10 LAN Connector for 10/100 Base-T Category 5 Ethernet cable RJ-45.
Refer to Section 3.4.8 for connector information.
3.5.2
M
ODES OF
O
PERATION
The RFPC Communicates to the Host system through a TCP/IP LAN connection
to control the ReFlex Power™ System. No other communication interface exists
3.5.3
D
EFAULT
O
PERATIONAL
C
ONDITIONS
When the RFPC module is first powered on, the following parameters are set to
default values:
•
RFPC LAN Parameters are at either Factory Default (DHCP enabled;
Auto-IP enabled) or User Default settings.
•
All Modules are in initial power up default state, relays, if present, are
open.
•
All status reporting data structures are clear: including the Protection
Event Status Register, Standard Event Status Register, and
Error/Event Queue. Enable-masks are clear.
3.5.4
I
NITIAL
F
UNCTIONAL
T
ESTS
Slot positions count from left to right with the left most slot number in the first
chassis designated as 1. The first chassis in the set of chassis contains slots 1
through 12 (Figure 3-6). The first chassis is the one with output connections
installed, but no input connections installed, (these can be seen on the rear of the
ReFlex Power™ chassis). The second chassis contains slots 13-24 and so forth
through all chassis in the system.