beautypg.com

17 ldf calibration for voltage range high – AMETEK ReFlex User Manual

Page 151

background image

AC Power Supplies

ReFlex Power™

4-66

M380056-01 Rev K

4.6.17

LDF

C

ALIBRATION FOR

V

OLTAGE

R

ANGE

H

IGH

The following procedure calibrates the Line drop fault supervisory.

1. Ensure that no load is connected to the output.

2. Issue clear and reset commands:

*CLS
*RST

3. Set the voltage range of the power supply to high

SOUR:VOLT:RANGE 1

4. Turn the unit on

OUTP:STATE 1

5. Program the output voltage to count 17000

CAL:OUTP:VOLT:COUNTS 17000

6. Send the calibration command to start the internal calibration

CAL:OUTP:LDF:CALC

7. Turn the unit off

OUTP:STATE 0

8. Send the system error query command to make sure calibration was successful.

SYST:ERR?

9. If there is no error returned at the system error query command then save the

calibration result with the following commands

CAL:UNLOCK “6867”
CAL:STORE
CAL:LOCK

10. Optional Commands:

Query the voltage calibration points:

CAL:OUTP:LDF:GAIN ?

11. Reset the unit

*RST

This manual is related to the following products: