beautypg.com

4 supervisory characteristics, 5 general characteristics – AMETEK ReFlex User Manual

Page 96

background image

ReFlex Power™

AC Power Supplies

M380056-01 Rev K

4-11

Crest Factor Range (version 3.0 and up only)

0 to 5

Crest Factor Accuracy

+/- .15, @ > 10% of RMS current range

Crest Factor Resolution

0.01

4.3.4

S

UPERVISORY

C

HARACTERISTICS

OverVoltage Protection (OVP)

Programmable OVP shall cause a shutdown in a trip event. It is programmable
from 1.4 to 110%, with a resolution of 0.027% of full scale, and an accuracy of
2%.

OverCurrent Protection (OCP)

Programmable OCP shall cause shutdown in a trip event. Programmable from
0.4 to 106% of full scale output current.
Accuracy: 3% of full scale
Resolution: 0.027% of full scale.

Over Temperature

Over temperature protection is implemented with hardware monitors that sense
excessive internal heat sink operating temperature, and shut down the power
converter.

Short-Circuit

The power supply shall withstand a continuous short-circuit across the output
connections, or from output to chassis ground, with no damage to the supply.

4.3.5

G

ENERAL

C

HARACTERISTICS

Input Voltage Range

103.5-253VAC with AC input; 270VDC, nominal; 210VDC, minimum to
300VDC, maximum; 314VDC, maximum for 2s; 364.5VDC, maximum for
450ms. Derate output power to 75% at 85VAC, and 85% at 95VAC.

This manual is related to the following products: