beautypg.com

7 command sets/drivers, 8 mechanical characteristics – AMETEK ReFlex User Manual

Page 98

background image

ReFlex Power™

AC Power Supplies

M380056-01 Rev K

4-13

Output Relays

Isolation relays are optionally provided on the main and auxiliary outputs.

4.3.7

C

OMMAND

S

ETS

/D

RIVERS

Command Description

SCPI Standard 1999 command language, through Controller Module

Response Description

SCPI Standard 1999 command language, through Controller Module

Command Execution Time

100ms from command request

4.3.8

M

ECHANICAL

C

HARACTERISTICS

Dimensions

4.2 inch wide, 6.75 inch high, and 15 inch deep

Weight

11.4 pound, maximum

Cooling Provisions

Operation at maximum limits of output power, ambient temperature, and
altitude requires adequate airflow through module: 40 CFM

Color

Black, color number 27038 per FED-STD-595

Acoustic Noise

The speed of the integral fans is linearly variable, as a function of internal
heatsink temperature rise, to minimize acoustic noise and extend the fan life.
The speed varies from nominally 50% of full-speed to full-speed as the
heatsink temperature varies with ambient temperature and power dissipation
resulting from the output load.

This manual is related to the following products: