beautypg.com

3 specifications, 1 product matrix, 2 output characteristics – AMETEK ReFlex User Manual

Page 174: Voltage accuracy, Voltage ripple/noise, Voltage temperature drift, Voltage line plus load regulation, Voltage load transient, Specifications

background image

ReFlex Power™

Fixed Power DC Power Supply

M380056-01 Rev J

5-5

5.3

SPECIFICATIONS

All specifications are valid after a 30-minute warm-up time. Module can be used
at reduced accuracy immediately following power-on. All accuracy specifications
are plus/minus variations around the nominal parameter values, unless otherwise
noted. Unless otherwise specified, requirements apply at the front panel output
terminals, and with remote sense leads connected to front panel terminals.
Performance specifications are valid following calibration at 25 °C, +/- 5 °C

5.3.1

P

RODUCT

M

ATRIX

Model

Output

Current Rating

Power Rating

FPDC

+5V DC

10 A

50W

-5V DC

5 A

25W

+15V DC

3 A

45W

-15V DC

3 A

45W

5.3.2

O

UTPUT

C

HARACTERISTICS

V

OLTAGE

A

CCURACY

+5VDC and –5 VDC: +/- 52 mV
+15VDC and –15VDC: +/-200 mV
All at 25 °C, +/-5 °C

V

OLTAGE

R

IPPLE

/N

OISE

(measured with 20Hz to 20MHz bandwidth)

+5VDC: 150 mV peak-peak
-5VDC: 80 mV peak-peak
+15VDC and –15VDC: 150 mV peak-peak

V

OLTAGE

T

EMPERATURE

D

RIFT

0.02% of full-scale/°C, maximum

V

OLTAGE

L

INE

P

LUS

L

OAD

R

EGULATION

+5VDC and –5VDC: +20 mV, -100 mV
+15VDC and –15VDC: +/- 150 mV

V

OLTAGE

L

OAD

T

RANSIENT

Less than 4% deviation for a 25-75% of full-scale load step and back within DC
regulation limits after 400 usec