beautypg.com

6 dac offset calibration for voltage range low – AMETEK ReFlex User Manual

Page 135

background image

AC Power Supplies

ReFlex Power™

4-50

M380056-01 Rev K

4.6.6

DAC

O

FFSET

C

ALIBRATION FOR

V

OLTAGE

R

ANGE

L

OW

This procedure calibrates the voltage DAC of the power supply.

1. Connect the meter between the output and the output return lead.

2. Set the voltmeter to read the DC voltage.

3. Ensure that no load is connected to the output.

4. Issue clear and reset commands:

*CLS
*RST

5. Set the OVP supervisory to limit 12000

CAL:OUTP:VOLT:PROT:COUNTS 12000

6. Set the OCP supervisory to maximum limit.

CAL:OUTP:CURR:PROT:COUNTS 4000

7. Set the voltage to zero

CAL:OUTP:VOLT:COUNTS 0

8. Set the current to maximum limit

CAL:OUTP:CURR:COUNTS 4000

9. DAC range is from 0 to 65535. Therefore set the DAC at the middle of the range

CAL:OUTP:DAC:COUNTS 32768

10. Turn the unit on.

OUTP:STATE 1

11. Set the DC loop off.

CAL:OUTP:DCLOOP OFF

12. Program the DAC to 0.5% below the middle range

CAL:OUTP:DAC:COUNTS 32456

13. Wait for the DC voltmeter to stabilize. Make an accurate measurement and then

enter the DC voltage using following command. User should enter the voltage
including sign (Ex: For Negative 4.15631 enter –4.15631)

CAL:OUTP:DAC:POINT1