AMETEK ReFlex User Manual
Reflex power
Table of contents
Document Outline
- M380056-01_Cvr-Sfty-Wrnty
- M380056-01_01_TOC_Intro
- SECTION 1 SYSTEM OVERVIEW
- 1.1 INTRODUCTION TO REFLEX POWERTM
- 1.2 FEATURES
- 1.3 SPECIFICATIONS
- 1.4 MINIMUM REQUIREMENTS
- 1.5 REFLEX POWER™ FIRMWARE COMPATIBILITY
- SECTION 1 SYSTEM OVERVIEW
- M380056-01_02_Mnfm
- SECTION 2 MAINFRAME
- 2.1 GENERAL DESCRIPTION
- 2.2 FEATURES
- 2.3 SPECIFICATIONS
- 2.4 INSTALLATION
- SECTION 2 MAINFRAME
- M380056-01_03_Cntrlr
- SECTION 3 CONTROLLER
- 3.1 GENERAL DESCRIPTION
- 3.2 FEATURES
- 3.3 SPECIFICATIONS
- 3.4 INSTALLATION
- 3.5 OPERATION
- SECTION 3 CONTROLLER
- M380056-01_04_AC
- SECTION 4 AC POWER SUPPLY (ACPS)
- 4.1 GENERAL DESCRIPTION
- 4.2 FEATURES
- 4.3 SPECIFICATIONS
- 4.4 INSTALLATION
- 4.5 OPERATION
- 4.6 CALIBRATION
- 4.6.1 Scope
- 4.6.2 Recommended Calibration Equipment
- 4.6.3 Calibration Setup
- 4.6.4 CalPot Calibration for Voltage Range Low
- 4.6.5 CalPot Calibration Voltage Range High
- 4.6.6 DAC Offset Calibration for Voltage Range Low
- 4.6.7 DAC Offset Calibration for Voltage Range High
- 4.6.8 Voltage ADC Offset Calibration for Voltage Range Low
- 4.6.9 Voltage ADC Offset Calibration for Voltage Range High
- 4.6.10 Current ADC Offset Calibration for Voltage Range Low
- 4.6.11 Current ADC Offset Calibration for Voltage Range High
- 4.6.12 High Speed Supervisory Calibration for Voltage Range Low
- 4.6.13 High Speed Supervisor Calibration for Voltage Range High
- 4.6.14 Voltage Calibration for Voltage Range Low
- 4.6.15 Voltage Calibration for Voltage Range High
- 4.6.16 LDF Calibration for Voltage Range Low
- 4.6.17 LDF Calibration for Voltage Range High
- 4.6.18 Current Calibration for Voltage Range Low
- 4.6.19 Current Calibration for Voltage Range High
- 4.6.20 Hall Calibration for Voltage Range Low (5 KHz Unit)
- 4.6.21 Hall Calibration for Voltage Range High (5 KHz Unit)
- 4.6.22 Hall Calibration for Voltage Range Low (1.2 KHz Unit)
- 4.6.23 Hall Calibration for Voltage Range High (1.2 KHz Unit)
- SECTION 4 AC POWER SUPPLY (ACPS)
- M380056-01_05_FPDC
- SECTION 5 FIXED POWER DCPOWER SUPPLY
- 5.1 GENERAL DESCRIPTION
- 5.2 FEATURES
- 5.3 SPECIFICATIONS
- 5.4 INSTALLATION
- 5.5 OPERATION
- 5.6 CALIBRATION
- 5.7 PERFORMANCE VERIFICATION
- SECTION 5 FIXED POWER DCPOWER SUPPLY
- M380056-01_06_DC
- SECTION 6 DC POWER SUPPLIES
- 6.1 GENERAL DESCRIPTION
- 6.2 FEATURES
- 6.3 SPECIFICATIONS
- 6.3.1 Product Matrix
- 6.3.2 Output Characteristics
- Voltage Programming Range
- Voltage Digital Programming Accuracy
- Voltage Digital Programming Resolution
- Voltage Ripple/Noise (measured with 20Hz to 20MHz bandwidth)
- Voltage Temperature Drift
- Voltage Stability
- Voltage Load Regulation
- Voltage Line Regulation
- Voltage Load transient
- Voltage Line transient
- Remote Sense Capability
- Voltage Ramp Time
- Current Programming Range
- Current Digital Programming Accuracy
- Current Digital Programming Resolution
- Current Ripple/Noise (measured with 20Hz to 300kHz bandwidth)
- Current Temperature Drift
- Current Stability
- Current Line Regulation
- Current Load Regulation
- 6.3.3 Measurement
- 6.3.4 Supervisory Characteristics
- 6.3.5 General Characteristics
- 6.3.6 Input/Output Connections
- 6.3.7 Command-Sets/Drivers
- 6.3.8 Mechanical Characteristics
- 6.3.9 Environmental Characteristics
- 6.3.10 Regulatory Agency Compliance
- 6.4 INSTALLATION
- 6.4.1 Introduction
- 6.4.2 Initial Inspection
- 6.4.3 Location Considerations
- 6.4.4 Installation
- 6.4.5 Input Power Requirements
- 6.4.6 AC/DC Input Overcurrent Protection
- 6.4.7 AC/DC Input Disconnect Device
- 6.4.8 Connectors
- RFP DC-16-20 Mating Connector Kit
- Recommended Tools (not included with Mating Connector kit)
- RFP-D1016-021-XXXX Interface Connector
- RFP-D1016-021-XXXX Interface Pinout
- Optional Interface Connector Accessories
- RFP-D1065-5A1-XXXX Mating Connector Kit
- Recommended Tools (not included with Mating Connector kit)
- RFP-D1065-5A1-XXXX Interface Pinout
- Optional Interface Connector Accessories
- RFP-D2033-030-XXXX Mating Connector Kit
- Recommended Tools (not included with Mating Connector kit)
- RFP-D2033-030-XXXX, Interface Connector:
- RFP-D2033-030-XXXX Interface Pinout
- Optional Interface Connector Accessories
- RFP-D2050-025-XXXX, RFP-D2050-020-XXXX Mating Connector Kit
- Recommended Tools (not included with Mating Connector kit)
- RFP-D2050-025-XXXX, RFP-D2050-020-XXXX Interface Connector:
- RFP-D2050-025-XXXX, RFP-D2050-020-XXXX Interface Pinout
- Optional Interface Connector Accessories
- RFP-D2120-8A3-XXXX Mating Connector Kit
- Recommended Tools (not included with Mating Connector kit)
- RFP-D2120-8A3-XXXX, Interface Connector:
- RFP-D2120-8A3-XXXX Interface Pinout
- Optional Interface Connector Accessories
- RFP-D2450-2A3-XXXX Mating Connector Kit
- Recommended Tools (Not Included with Mating Connector Kit)
- RFP-D2450-2A3-XXXX Interface Connector:
- RFP-D2450-2A3-XXXX Interface Pinout
- Optional Interface Connector Accessories
- DC Output Connector:
- DC Output Connector Accessories
- RFP-D1065-5A1-XXXX DC Output Connector:
- DC Output Connector Accessories
- RFP-D2033-030-XXXX DC Output Connector:
- DC Output Connector Accessories
- RFP-D2050-025-XXXX, RFP-D2050-020-XXXX DC Output Connector:
- DC Output Connector Accessories
- RFP-D2120-8A3-XXXX DC Output Connector:
- DC Output Connector Accessories
- RFP-D2450-2A3-XXXX DC Output Connector:
- DC Output Connector Accessories
- Remote Sense
- Module Enable (ENA)
- 6.4.9 Wire Selection
- 6.5 OPERATION
- 6.6 CALIBRATION
- SECTION 6 DC POWER SUPPLIES
- M380056-01_07_Loads
- SECTION 7 ACTIVE LOADS
- 7.1 GENERAL DESCRIPTION
- 7.2 FEATURES
- 7.3 SPECIFICATIONS
- 7.3.1 Product Matrix
- 7.3.2 Input Characteristics
- 7.3.3 Supervisory Characteristics
- Supervisory Protection
- Redundant Overvoltage Threshold
- Redundant Overvoltage Threshold Accuracy
- Redundant Overcurrent Threshold
- Redundant Overcurrent Threshold Accuracy
- Overpower Threshold
- Overpower Resolution
- Overpower Accuracy
- Reverse Voltage Protection
- Reverse Voltage Protection Accuracy
- Overtemperature Protection
- 7.3.4 General Characteristics
- 7.3.5 Command Sets/Drivers
- 7.3.6 Mechanical Characteristics
- 7.3.7 Environmental Characteristics
- 7.4 INSTALLATION
- 7.5 OPERATION
- 7.6 CALIBRATION
- 7.6.1 Scope
- 7.6.2 Recommended Calibration Equipment
- 7.6.3 Calibration Setup
- 7.6.4 CalPot Calibration for High Power Active Load (HPAL)
- 7.6.5 HPAL High Range Current Calibration
- 7.6.6 HPAL Low Range Current Calibration
- 7.6.7 HPAL Low Range Current Calibration
- 7.6.8 HPAL Voltage Calibration – Part I of V
- 7.6.9 HPAL Voltage Calibration – Part II of V
- 7.6.10 HPAL Voltage Calibration – Part III of V
- 7.6.11 HPAL Voltage Calibration – Part IV of V
- 7.6.12 HPAL Voltage Calibration – Part V of V
- 7.6.13 HPAL Resistance Calibration – Part I of V
- 7.6.14 HPAL Resistance Calibration – Part II of V
- 7.6.15 HPAL Resistance Calibration – Part III of V
- 7.6.16 HPAL Resistance Calibration – Part IV of V
- 7.6.17 HPAL Resistance Calibration – Part V of V
- 7.6.18 HPAL IAI Board Calibration
- 7.6.19 LPAL CalPot Calibration
- 7.6.20 Current Calibration for LPAL
- 7.6.21 LPAL Low Range Current Calibration
- 7.6.22 LPAL Voltage Calibration – PART I of V
- 7.6.23 LPAL Voltage Calibration – Part II of V
- 7.6.24 LPAL Voltage Calibration – PART III of V
- 7.6.25 LPAL Voltage Calibration – Part IV of V
- 7.6.26 LPAL Voltage Calibration – Part V of V
- 7.6.27 LPAL Resistance Calibration – Part I of V
- 7.6.28 LPAL Resistance Calibration – Part II of V
- 7.6.29 LPAL Resistance Calibration – Part III of V
- 7.6.30 LPAL Resistance Calibration – Part IV of V
- 7.6.31 LPAL Resistance Calibration Part V of V
- 7.6.32 LPAL IAI BOARD CALIBRATION
- SECTION 7 ACTIVE LOADS