beautypg.com

Dc input pinout, Dc input connector accessories, Remote sense – AMETEK ReFlex User Manual

Page 296

background image

ReFlex Power™

Active Loads

M380056-01 Rev J

7-21

DC

I

NPUT

P

INOUT

Figure 7-7. DC Input Connector and Wiring Diagram

Table 7-3. DC Input Pinout and Wire Information

Pin

Name

Function

Signal Level

Max Wire

Gauge

D

DCIN

INPUT:INPUT SOURCE

+500V; 500V, MAX TO
CHASSIS

8

B

DCIN_RTN

INPUT: RETURN FOR INPUT SOURCE
DCIN

0V; 500V, MAX TO CHASSIS

8

C

SNS

INPUT; REMOTE SENSE FOR DCIN

+500V; 500V, MAX TO
CHASSIS

16

A

SNS_RTN

INPUT REMOTE SENSE FOR
DCIN_RTN

0V; 500V, MAX TO CHASSIS

16

DC

I

NPUT

C

ONNECTOR

A

CCESSORIES

AMETEK P/N 5380452-01, Load Module, 9ft. Unterminated DC Input Cable
Assembly

R

EMOTE

S

ENSE

Remote sensing is used to compensate for the voltage drop that
occurs across the wires connecting the source to the input of the
Active Load modules. A separate pair of wires is routed to measure
the voltage at the source terminals where precise measurement of the
output voltage is desired.

The remote sense leads are connected at the DC INPUT connector
on the front panel of the modules. Refer to the section, DC Inputs, for
information on connector pinout. Connect the SNS terminal to the load
terminal connected to the module DCIN terminal, and the SNS-RTN
terminal to the load terminal connected to DCIN-RTN terminal.

Special care is required in routing the sensing leads to prevent noise
pickup or coupling to the power leads; refer to the section, Noise and
Impedance Effects. The sense leads should be a twisted-pair of AWG
#16-20 wire, and may require shielding in high noise environments.
Connect the shield to the shield ground terminal, CHAS-GND, of the
DC INPUT connector, as required to maximize its effectiveness.

This manual is related to the following products: