15 voltage calibration for voltage range high – AMETEK ReFlex User Manual
Page 148

ReFlex Power™
AC Power Supplies
M380056-01 Rev K
4-63
4.6.15
V
OLTAGE
C
ALIBRATION FOR
V
OLTAGE
R
ANGE
H
IGH
The following procedure calibrates the output voltage of the power supply. This is
five- point calibration procedure. Connect the meter between the output and the
output return lead. Set the voltmeter to read the AC voltage.
1. Ensure that no load is connected to the output.
2. Issue clear and reset commands:
*CLS
*RST
3. Set the voltage range of the power supply to high
SOUR
4. Set the current to maximum limit
CAL
5. Turn the unit on
OUTP
6. Set the OVP supervisory to limit 20261
CAL
7. Set the OCP supervisory to maximum limit.
CAL
8. Program the output voltage to 5% of the full scale voltage
CAL
9. Wait for AC voltage to stabilize. Measure the output voltage using the AC
voltmeter. Enter the measured voltage using following command
CAL
10. Program the output voltage to 27.5% of the full scale voltage
CAL
11. Wait for AC voltage to stabilize. Measure the output voltage using the AC
voltmeter. Enter the measured voltage using following command