Lan connector, Lan connector pinout, 5 operation – AMETEK ReFlex User Manual
Page 80: Operation
ReFlex Power™
ReFlex Power™ Controller
M380056-01 Rev J
3-17
LAN
C
ONNECTOR
Primary user interface to the ReFlex Power™ system via Ethernet connection
Type: RJ45, CAT 5 compatible; protocol conforms to IEEE 802.3 Ethernet-based LANs
Mating connector: Amphenol Socapex P/N RJF6MN, AMETEK P/N 856-993-07
Wire size: Standard CAT 5e 10/100-Base-T cable
Maximum length: 10 meters (can be extended subject to the environment and cable type).
LAN
C
ONNECTOR
P
INOUT
Pin
Name
Function
Signal Level
1
TX+
Transmit data positive, twisted differential pair with TX-
IEEE 802.3
2
TX-
Transmit data negative, twisted differential pair with TX+
IEEE 802.3
3
RX+
Receive data positive, twisted differential pair with RX-
IEEE 802.3
4
NA
N/A
5
NA
N/A
6
RX-
Receive data negative, twisted differential pair with RX+
IEEE 802.3
7
NA
N/A
8
NA
N/A
3.5
OPERATION
The ReFlex Power™ Controller (RFPC) module functions under remote control
through a host controller. The RFPC module serves as a communications portal
between the power supply modules and the remote host controller. All aspects of
operation could be achieved through use of commands that comply with the
requirements of the SCPI Standard 1999 command language. Additional discrete
digital control signals are available for dedicated hardware interface. All
connectors for control are accessible on the front panel.