beautypg.com

4 general characteristics, Range, Current – AMETEK ReFlex User Manual

Page 285: Input characteristics, Connector, Power factor, Current harmonic, Current inrush, Frequency, Brownout provisions

background image

Active Loads

ReFlex Power™

7-10

M380056-01 Rev J

7.3.4

G

ENERAL

C

HARACTERISTICS

AC INPUT POWER

R

ANGE

103.5-253VAC with AC input; 270VDC, nominal; 210VDC, minimum to 300VDC,
maximum; 314VDC, maximum for 2s; 364.5VDC, maximum for 450ms

C

URRENT

Non-linear pulsed current from full-wave rectified AC input; continuous DC
current from DC input

I

NPUT

C

HARACTERISTICS

Rectifier with capacitive input filter

C

ONNECTOR

Backplane-mounted connector

P

OWER

F

ACTOR

0.6, typical

C

URRENT

H

ARMONIC

Nonlinear AC input current from rectifier/capacitor-filter

C

URRENT

I

NRUSH

Inrush current protection at power-on with AC and DC input: 5A

PK

at 115VAC;

10A

PK

at 230VAC;

8.5A

PK

at 270VDC

F

REQUENCY

47-63Hz AC input; up to 132VAC in 400 Hz; DC Input

B

ROWNOUT

P

ROVISIONS

Sag to 65% of nominal for 450ms maximum at full output power with AC input
at ≥ 200VAC.
Surge to 135% of nominal for 450ms at full output with AC input ≤ 230VAC.

H

OLD

-U

P

T

IME

Dropout of AC input at zero for 10ms at full input power.

I

NPUT

P

OWER

V

OLTAGE

T

HRESHOLD

The input power voltage is monitored for under voltage conditions. External DC
input is disabled if operating voltage range is exceeded.

This manual is related to the following products: