4 general characteristics, Range, Current – AMETEK ReFlex User Manual
Page 285: Input characteristics, Connector, Power factor, Current harmonic, Current inrush, Frequency, Brownout provisions

Active Loads
ReFlex Power™
7-10
M380056-01 Rev J
7.3.4
G
ENERAL
C
HARACTERISTICS
AC INPUT POWER
R
ANGE
103.5-253VAC with AC input; 270VDC, nominal; 210VDC, minimum to 300VDC,
maximum; 314VDC, maximum for 2s; 364.5VDC, maximum for 450ms
C
URRENT
Non-linear pulsed current from full-wave rectified AC input; continuous DC
current from DC input
I
NPUT
C
HARACTERISTICS
Rectifier with capacitive input filter
C
ONNECTOR
Backplane-mounted connector
P
OWER
F
ACTOR
0.6, typical
C
URRENT
H
ARMONIC
Nonlinear AC input current from rectifier/capacitor-filter
C
URRENT
I
NRUSH
Inrush current protection at power-on with AC and DC input: 5A
PK
at 115VAC;
10A
PK
at 230VAC;
8.5A
PK
at 270VDC
F
REQUENCY
47-63Hz AC input; up to 132VAC in 400 Hz; DC Input
B
ROWNOUT
P
ROVISIONS
Sag to 65% of nominal for 450ms maximum at full output power with AC input
at ≥ 200VAC.
Surge to 135% of nominal for 450ms at full output with AC input ≤ 230VAC.
H
OLD
-U
P
T
IME
Dropout of AC input at zero for 10ms at full input power.
I
NPUT
P
OWER
V
OLTAGE
T
HRESHOLD
The input power voltage is monitored for under voltage conditions. External DC
input is disabled if operating voltage range is exceeded.