ReFlex Power™

AC Power Supplies

M380056-01 Rev K

4-57

4.6.11

C

URRENT

ADC

O

FFSET

C

ALIBRATION FOR

V

OLTAGE

R

ANGE

H

IGH

The following procedure calibrates offset of the current ADC for the voltage range
high.

1. Ensure that no load is connected to the output.

2. Issue clear and reset commands:

*CLS
*RST

3. Set the voltage range of the power supply to high

SOUR:VOLT:RANGE 1

4. Perform the voltage ADC offset calibration

CAL:MEAS:IADC:OFFSET:CALC

5. Send the system error query command to make sure calibration was successful.

SYST:ERR?

6. If there is no error returned at the system error query command then save the

calibration result with the following command

CAL:UNLOCK “6867”
CAL:STORE
CAL:LOCK

7. Optional Commands

To query the voltage ADC offset:

CAL: MEAS:IADC:OFFSET ?

8. Reset the unit

*RST