AMETEK ReFlex User Manual
Page 162

ReFlex Power™
AC Power Supplies
M380056-01 Rev K
4-77
14. Set the output frequency to 500Hz
SOUR
15. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL
16. Set the output frequency to 1000Hz
SOUR
17. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL
18. Set the output frequency to 2000Hz
SOUR
19. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL
20. Set the output frequency to 3000Hz
SOUR
21. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL
22. Set the output frequency to 4000Hz
SOUR
23. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL
24. Set the output frequency to 5000Hz
SOUR
25. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current using following command
CAL