Voltage ramp time, Current programming range, Current digital programming accuracy – AMETEK ReFlex User Manual
Page 212: Current digital programming resolution, Current temperature drift, Current stability

ReFlex Power™
DC Power Supplies
M380056-01 Rev K
6-9
V
OLTAGE
R
AMP
T
IME
The time required for the output voltage to change from a specified initial value
to another programmed value, +/-0.1%, does not exceed 20 ms. The allowed
voltage change includes the following worse case conditions:
•
Down-programming, at no load, from full-scale output voltage to zero, +/-
0.5% of full-scale
•
Up-programming, at full load, from zero to full-scale output voltage
For up-programming, the output voltage ramp speed is proportional to the
programmed value of the output current. To achieve the 20ms ramp time for a
programmed voltage step change from zero to full-scale, and with full output
load, the output current must be programmed to full-scale. To maintain the
20ms ramp time with programmed values of output current at less than full-
scale, the programmed voltage step change must be correspondingly reduced.
C
URRENT
P
ROGRAMMING
R
ANGE
0 to 102% of full-scale
C
URRENT
D
IGITAL
P
ROGRAMMING
A
CCURACY
RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:
0.1% of full-scale plus 0.1% of set point, at 25 °C, +/- 5 °C
RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:
0.1% of full-scale plus 0.2% of set point, at 25 °C, +/- 5 °C
C
URRENT
D
IGITAL
P
ROGRAMMING
R
ESOLUTION
RFP-D1016-021-XXXX:
1.28mA
RFP-D1065-5A1-XXXX:
0.32mA
RFP-D2033-030-XXXX:
1.9mA
RFP-D2050-020-XXXX:
1.3mA
RFP-D2050-025-XXXX:
1.6mA
RFP-D2120-8A3-XXXX:
0.6mA
RFP-D2450-2A3-XXXX:
0.14mA
C
URRENT
R
IPPLE
/N
OISE
(
MEASURED WITH
20H
Z TO
300
K
H
Z BANDWIDTH
)
0.05% of full-scale, RMS
C
URRENT
T
EMPERATURE
D
RIFT
RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:
0.025% of full-scale/°C
RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX,
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:
0.03% of full-scale/°C
C
URRENT
S
TABILITY
0.05% of full-scale after 24 hours at constant line, load, and temperature