Discovery from hp sim – HP Storage Essentials NAS Manager Software User Manual
Page 78
Discovering NAS Devices, Tape Libraries, Switches and Storage Systems
46
•
When you discover a Sun StorEdge or QLogic SNMP switch in HP SE, you do not need to
provide a password if you discover it in HP SE. HP SIM requires a password.
•
The management server does not support provisioning for Sun StorEdge and QLogic switches.
Only the active zone set and its zone members are reported.
•
To manage a fabric of Sun StorEdge and/or QLogic switches, every switch in the fabric must be
included in the discovery list. If a switch is not included in the discovery list, it may show up as a
generic host system.
•
No ports are reported for uninstalled blades or GBICs.
•
The default SNMP trap listener port for all Sun StorEdge switches is 162. To change this port,
see ”
Changing the SNMP Trap Listener Port for Sun StorEdge Switches
•
To receive events from Sun StorEdge switches, verify the SNMP trap community string is set to
public in SANbox Manager or via telnet. Also, make sure the SNMP traps are configured to be
sent to the management server. See ”
” on page 465 for more information.
Keep in mind the following for QLogic SMI-S switches:
•
A user name and password are required to discover any SMI-S switch.
NOTE:
You must perform Get Details or Discovery Data Collection to obtain all available
information from QLogic SMI-S switches—otherwise, attributes such as vendor, fabric, and port
information will be missing for the QLogic SMI-S switches. You may see an error replicating the
switch fabric name for QLogic-based switches. This error can be ignored.
Discovery from HP SIM
IMPORTANT:
Provide the SNMP credentials in the WBEM settings section on the System Protocol
Settings page (Options > Protocol Settings > System Protocol Settings). Only the WBEM
default credentials are passed from HP SIM to HP SE. Any default credential information you set up
in regards to SNMP is not passed from HP SIM to HP SE.
To discover a Sun StorEdge or QLogic switch in HP Insight Manager, provide the following:
•
System name or primary IP address of the a Sun StorEdge or QLogic switch you want to
discover. See ”
Adding an IP Range for Scanning
” on page 28 for more information.
•
Do one of the following:
• For Sun StorEdge or QLogic switches with SNMP connections:
Provide the user name for the switch. This is the public community SNMP string for the switch.
• For QLogic switches with SMI-S connections:
Provide the SMI-S user name.
•
HP SIM does not allow blank passwords. Do one of the following:
• Enter anything for the password for Sun StorEdge and QLogic SNMP switches.
• A password is required on SMI-S switches. Enter the password.
- Storage Essentials Report Designer Software Storage Essentials Enterprise Edition Software Storage Essentials Provisioning Manager Software Storage Essentials Chargeback Manager Software Storage Essentials Backup Manager Software Storage Essentials Global Reporter Software Storage Essentials File System Viewer Software Storage Essentials Exchange Viewer Software BladeSystem p-Class Power Distribution